HP ProLiant ML310 Generation 3 Server
Maintenance and Service Guide
May 2006 (Fourth Edition)
Part Number 393771-004
Vista de pagina 0
1 2 3 4 5 6 ... 67 68

Indice de contenidos

Pagina 1 - Part Number 393771-004

HP ProLiant ML310 Generation 3 Server Maintenance and Service Guide May 2006 (Fourth Edition) Part Number 393771-004

Pagina 2 - Audience assumptions

Customer self repair 10 Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" o

Pagina 3 - Contents

Customer self repair 11

Pagina 4 - Contents 4

Customer self repair 12

Pagina 5 - Customer self repair

Customer self repair 13

Pagina 6

Customer self repair 14

Pagina 7 - Customer Self Repair

Illustrated parts catalog 15 Illustrated parts catalog In this section Mechanical components ...

Pagina 8 - Customer self repair 8

Illustrated parts catalog 16 Item Description Assembly part number Spare part number Customer self repair (on page 5) 2 Access panel — 405364-001

Pagina 9

Illustrated parts catalog 17 1Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP q

Pagina 10 - Reparo feito pelo cliente

Illustrated parts catalog 18

Pagina 11 - Customer self repair 11

Illustrated parts catalog 19 System components Item Description Assembly part number Spare part number Customer self repair (on page 5) System co

Pagina 12 - Customer self repair 12

© Copyright 2005, 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Pagina 13 - Customer self repair 13

Illustrated parts catalog 20 Item Description Assembly part number Spare part number Customer self repair (on page 5) e) 3.2-GHz Intel® Pentium® 4

Pagina 14 - Customer self repair 14

Illustrated parts catalog 21 2Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également con

Pagina 15 - Illustrated parts catalog

Illustrated parts catalog 22

Pagina 16

Removal and replacement procedures 23 Removal and replacement procedures In this section Required tools...

Pagina 17

Removal and replacement procedures 24 • Avoid hand contact by transporting and storing products in static-safe containers. • Keep electrostatic-sen

Pagina 18

Removal and replacement procedures 25 WARNING: When installing a server in a telco rack, be sure that the rack frame is adequately secured to the

Pagina 19 - System components

Removal and replacement procedures 26 2. Remove the bezel. To replace the component, reverse the removal procedure. Access panel WARNING: To re

Pagina 20

Removal and replacement procedures 27 Hot-plug SCSI hard drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server

Pagina 21

Removal and replacement procedures 28 IMPORTANT: When hot-plug SATA hard drives are installed, SATA LED functionality and full SATA hot-plug capab

Pagina 22

Removal and replacement procedures 29 5. Remove the non-hot-plug hard drive cage. To replace the component, reverse the removal procedure. Hard dr

Pagina 23 - Safety considerations

Contents 3 Contents Customer self repair...

Pagina 24 - Rack warnings and cautions

Removal and replacement procedures 30 To replace the component, reverse the removal procedure. Hot-plug SCSI, SAS, or SATA hard drive cage To remov

Pagina 25 - Preparation procedures

Removal and replacement procedures 31 7. Remove the SCSI backplane. To replace the component, reverse the removal procedure. Hot-plug SAS or SATA

Pagina 26 - Access panel

Removal and replacement procedures 32 To replace the component, reverse the removal procedure. Diskette drive CAUTION: To prevent improper cooli

Pagina 27 - Hot-plug SCSI hard drive

Removal and replacement procedures 33 5. Remove the CD-ROM or DVD-ROM drive. To replace the component, reverse the removal procedure. Air baffle T

Pagina 28 - Non-hot-plug hard drive cage

Removal and replacement procedures 34 1. Power down the server (on page 25). 2. Remove the bezel (on page 25). 3. Remove the access panel ("A

Pagina 29 - Hard drive (non-hot-plug)

Removal and replacement procedures 35 4. Remove the DIMM. To replace the component, reverse the removal procedure. IMPORTANT: DIMMs do not seat

Pagina 30 - Hot-plug SCSI backplane

Removal and replacement procedures 36 Channel A Channel A Channel B Channel B Total memory Mode Slot 1 Slot 2 Slot 3 Slot 4 1 GB 1 GB 2

Pagina 31

Removal and replacement procedures 37 7. Remove the processor, proceed as shown in the following illustration. To replace the component: 1. Instal

Pagina 32 - CD-ROM/DVD-ROM drive

Removal and replacement procedures 38 CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an "X" pa

Pagina 33 - Power supply

Removal and replacement procedures 39 Fan assembly To remove the component: 1. Power down the server (on page 25). 2. Remove the bezel (on page 25

Pagina 34

Contents 4 Front panel components ...

Pagina 35

Removal and replacement procedures 40 1. Power down the server (on page 25). 2. Remove the bezel (on page 25). 3. Remove the access panel ("A

Pagina 36 - Processor assembly

Removal and replacement procedures 41 • Do not attempt to recharge the battery. • Do not expose the battery to temperatures higher than 60°C (140

Pagina 37

Removal and replacement procedures 42 10. Remove the system board. To replace the component, reverse the removal procedure. After you replace the s

Pagina 38 - PCI expansion board

Cabling 43 Cabling In this section Hot-plug SCSI hard drive cabling ...

Pagina 39 - Power button/LED board

Cabling 44 Non-hot-plug SCSI hard drive cabling Item Description 1 SCSI cable 2 Power cable Hot-plug SATA hard drive cabling Item Descripti

Pagina 40 - Battery

Cabling 45 Non-hot-plug SATA hard drive cabling Item Description 1 SATA cable 2 Power cable SAS hard drive cabling Item Description 1 Power

Pagina 41 - System board

Diagnostic tools 46 Diagnostic tools In this section Survey Utility...

Pagina 42

Diagnostic tools 47 Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each ev

Pagina 43 - Cabling

Component identification 48 Component identification In this section Front panel components ...

Pagina 44

Component identification 49 Item Description 6 CD-ROM/DVD-ROM drive Front panel LEDs and buttons Item Description Status 1 CD-ROM/DVD-ROM dri

Pagina 45 - SAS hard drive cabling

Customer self repair 5 Customer self repair HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow fo

Pagina 46 - Diagnostic tools

Component identification 50 Rear panel components Item Description 1 Power cord connector 2 Mouse connector 3 Keyboard connector 4 Serial conne

Pagina 47 - ROMPaq disaster recovery

Component identification 51 Item Description Status 1 NIC link LED On = Link Off = No link 2 NIC activity LED Flashing = Activity Off = No a

Pagina 48 - Component identification

Component identification 52 Items Description 20 System fan connector * x8 PCI Express cards are supported, but will run at x4 speeds. System mai

Pagina 49 - Front panel LEDs and buttons

Component identification 53 System board LEDs Item Description Status 1 PPM failure Amber = PPM failed or missing Off = Normal 2 DIMM 4 fail

Pagina 50 - Rear panel LEDs

Component identification 54 Item Description Status 11 Single bit error Amber = Single bit error limit has been exceeded Off = Normal 12 System f

Pagina 51 - System board components

Component identification 55 SCSI IDs Hot-plug SCSI hard drive LEDs Item Description Status 1 Activity status On = Drive activity Flashing =

Pagina 52 - System maintenance switch

Component identification 56 Item Description Status 3 Fault status On = Drive failure Flashing = Fault-process activity Off = No fault-process ac

Pagina 53 - System board LEDs

Component identification 57 Hot-plug SAS and SATA device numbers SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue)

Pagina 54

Component identification 58 Online/activity LED (green) Fault/UID LED (amber/blue) Interpretation On, off, or flashing Steadily blue The drive is o

Pagina 55 - SCSI IDs

Component identification 59 Item Description 2 Processor fan

Pagina 56

Customer self repair 6 • Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pi

Pagina 57 - SAS and SATA hard drive LEDs

Specifications 60 Specifications In this section Server specifications...

Pagina 58

Specifications 61 Specification Value Maximum wet bulb temperature 28°C (82.4°F) Relative humidity (noncondensing)** Operating 20% to 80% Non-oper

Pagina 59 - 2 Processor fan

Specifications 62 CD-ROM drive specifications Specification Value Disk formats CD-ROM (modes 1 and 2); mixed mode (audio and data combined); CD-D

Pagina 60 - Specifications

Specifications 63 Item 36.4-GB Ultra320 SCSI drive 80-GB SATA drive Height 1.0 in (One-third height) 1.028 in Width 4.0 in 4.0 in Interface Ultr

Pagina 61

Specifications 64 Specification Value Stop time < 5 s (single); < 30 s (multisession) Laser parameters Type Semiconductor laser GaAs Wave len

Pagina 62 - Hard drive specifications

Acronyms and abbreviations 65 Acronyms and abbreviations ASR Automatic Server Recovery DDR double data rate DIMM dual inline memory module ECC er

Pagina 63 - DVD-ROM drive specifications

Acronyms and abbreviations 66 RAID redundant array of inexpensive (or independent) disks RBSU ROM-Based Setup Utility SAS serial attached SCSI SA

Pagina 64

Index 67 A AC power supply 33, 50 access panel 26 ADU (Array Diagnostic Utility) 46 Array Diagnostic Utility (ADU) 46 ASR (Automatic Server R

Pagina 65 - Acronyms and abbreviations

Index 68 S safety considerations 23 SAS backplane 31 SAS cabling 45 SAS drives 57 SAS hard drive 27 SAS hard drive LEDs 57 SAS-SATA hard

Pagina 66

Customer self repair 7 In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo s