5
Under the connection conditions shown below, operation using a combination cable is assured up to 16 sets.
Conditions: 1 Length of RS-232C cable connecting PC to PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S: 5 m
2 Combination cable length: 5 m each
3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable)
For 1 strand, suitable for AWG28:
Cross-section area = 0.08 mm
2
7 strands × π r
2
= 7 × 3.14 × 0.06
2
= 0.079 mm
2
0.08 mm
2
Note
For details on the number of displays that can be connected in series using the video OUT terminal (INPUT1, 4), refer to
section 2.3, Part Names.